Lavoisier S.A.S.
14 rue de Provigny
94236 Cachan cedex
FRANCE

Heures d'ouverture 08h30-12h30/13h30-17h30
Tél.: +33 (0)1 47 40 67 00
Fax: +33 (0)1 47 40 67 02


Url canonique : www.lavoisier.fr/livre/electricite-electronique/cmos-capacitive-sensors-for-lab-on-chip-applications-a-multidisciplinary-approach-analog-circuits-et-signal-processing/ghafar-zadeh/descriptif_2429716
Url courte ou permalien : www.lavoisier.fr/livre/notice.asp?ouvrage=2429716

CMOS Capacitive Sensors for Lab-on-Chip Applications, 2010 A Multidisciplinary Approach Analog Circuits and Signal Processing Series

Langue : Anglais

Auteurs :

Couverture de l’ouvrage CMOS Capacitive Sensors for Lab-on-Chip Applications
1.1 Overview of Lab-on-Chip Laboratory-on-Chip (LoC) is a multidisciplinary approach used for the miniaturization, integration and automation of biological assays or procedures in analytical chemistry [1?3]. Biology and chemistry are experimental sciences that are continuing to evolve and develop new protocols. Each protocol offers step-by-step laboratory instructions, lists of the necessary equipments and required biological and/or chemical substances [4?7]. A biological or chemical laboratory contains various pieces of equipment used for performing such protocols and, as shown in Fig. 1.1, the engineering aspect of LoC design is aiming to embed all these components in a single chip for single-purpose applications. 1.1.1 Main Objectives of LoC Systems Several clear advantages of this technology over conventional approaches, including portability, full automation, ease of operation, low sample consumption and fast assays time, make LoC suitable for many applications including. 1.1.1.1 Highly Throughput Screening To conduct an experiment, a researcher fills a well with the required biological or chemical analytes and keeps the sample in an incubator for some time to allowing the sample to react properly. Afterwards, any changes can be observed using a microscope. In order to quickly conduct millions of biochemical or pharmacolo- cal tests, the researchers will require an automated highly throughput screening (HTS) [8], comprised of a large array of wells, liquid handling devices (e.g., mic- channel, micropump and microvalves [9?11]), a fully controllable incubator and an integrated sensor array, along with the appropriate readout system.

1: Introduction. 1.1 Overview of Lab-on-Chip. 1.2 From Macro to Micro Bioassays. 1.3 CMOS-Based Lab-on-Chips. 1.4 Objectives and Organization of book.

2: CMOS sensing electrodes. 2.1 On-chip microelectrode configurations. 2.2 Micromachining gold electrode on CMOS chip. 2.3 Electrical model of capacitive sensing electrodes. 2.4 Summary.

3: Capacitive Biochemical Interfaces. 3.1 Biochemical capacitive sensing methods. 3.2 Design of recognition element: An example for CGM. 3.3 Summary.

4: Capacitive Interface circuits. 4.1 LBCS vs. MBCS. 4.2 LBCS methods. 4.3 Core-CBCM interface circuit. 4.4 Core-CBCM ?? capacitive sensor. 4.5 Core-CBCM capacitive sensing system. 4.6 Summary.

5: Microfluidic Packaging Techniques. 5.1 Microfluidic packaging methods. 5.2 Direct-write microfabrication process. 5.3 Direct-write microfluidic packaging procedure. 5.4 Emerging applications of DWFP. 5.5 Summary.

6: Present and Future Technology of Capacitive Biosensors. 6.1 Conventional impedometric and capacitive measurement systems. 6.2 Handheld impedance measurement systems. 6.3 Towards fully integrated capacitive sensing LoC. 6.4 Summary.

Ebrahim Ghafar-Zadeh received the BSc and MSc degrees in Electrical Engineering from KNT and Tehran Universities, Tehran, Iran, in 1992 and 1994, respectively. In 1994 he joints the electrical engineering department at SCU University, Ahvaz, Iran as faculty memeber. During 2004-2008, he pursued a PhD degree in electrical engineering at Ecole Polytechnique de Montreal, Canada. In January 2008 and September 2008, he received two fellowship award from NSERC Canada and ReSMiQ Quebec, Canada which allowed him to continue his research for fully integrated bacteria detection. The research interests of Dr. Ghafar-zadeh include the circuit and system design, implementation and packaging technologies for lab-on-chip applications.

Mohamad Sawan received his BSc in Electrical Engineering from Université Laval (1984), and MSc (1986) and PhD (1990) both in Electrical Engineering from Université de Sherbrooke. He then completed post-doctoral training at Montréal's McGill University in 1991, and in that same year, joined École Polytechnique de Montréal, where he is currently a Professor of Microelectronics. Dr. Sawan's scientific interests focus on the design and testing of mixed-signal (analog, digital and RF) circuits and systems; digital and analog signal processing; and the modelling, design, integration, assembly and validation of advanced wirelessly powered and controlled monitoring and measurement techniques. These topics are oriented toward biomedical implantable devices and telecommunications applications. Dr. Sawan is holder of the Canada Research Chair in Smart Medical Devices. He heads the Microsystems Strategic Alliance of Québec – ReSMiQ and is founder of the Eastern Canada Chapter of the IEEE-Solid State Circuits Society. He also founded the International IEEE-NEWCAS conference, co-founded the International Functional Electrical Stimulation Society, and founded the Polystim Neurotechnologies Laboratoryat Ecole Polyte

This unique multidisciplinary book describes all the required components for the design of a CMOS capacitive biosensor It offers an extensive recent review of literature on using CMOS processes for Lab-on-Chip applications It emphasis on practical aspects of fully integrated capacitive biosensors Includes supplementary material: sn.pub/extras

Date de parution :

Ouvrage de 146 p.

15.5x23.5 cm

Disponible chez l'éditeur (délai d'approvisionnement : 15 jours).

Prix indicatif 105,49 €

Ajouter au panier

Date de parution :

Ouvrage de 146 p.

15.5x23.5 cm

Disponible chez l'éditeur (délai d'approvisionnement : 15 jours).

Prix indicatif 105,49 €

Ajouter au panier